Open Access
Precise Measurement of Wear Rate Method for ASTM G-99 Wear Test
Esad Kaya1, Koray Kılıçay2*, İsmail  Bayar 3, Mustafa Ulutan4
1Mechanical Engineering Department, ESOGU , Eskişehir, Turkey
2Mechanical Engineering Department, ESOGU , Eskişehir, Turkey
3Mechanical Engineering Department, ESOGU, Eskişehir, Turkey
4Mechanical Engineering Department, ESOGU  , Eskişehir, Turkey
* Corresponding author: kkilicay@ogu.edu.tr

Presented at the Ist International Symposium on Innovative Approaches in Scientific Studies (ISAS 2018), Kemer-Antalya, Turkey, Apr 11, 2018

SETSCI Conference Proceedings, 2018, 2, Page (s): 66-66 , https://doi.org/

Published Date: 23 June 2018    | 1087     9

Abstract

ASTM G99 also known as pin-on-disk method is widely used to determine the tribological behavior of materials. But in general, there is always uncertainties in the results of wear test method. Different attempts have been made by scientists to eliminates these uncertainties such as calculation of worn surface area and wear rate. In this study, the effect of worn surface profile measurement factor to the uncertainty of the wear rate is researched. A wear test had been done in accordance with ASTM G99 norm under the 3 different wear loads. Exact measurement of wear rates according to norm had been showed. Results are discussed respectively for all control groups.  

Keywords - Wear Experiment, Surface Profile measurement, Wear Rate Calculation

References

SETSCI 2024
info@set-science.com
Copyright © 2024 SETECH
Tokat Technology Development Zone Gaziosmanpaşa University Taşlıçiftlik Campus, 60240 TOKAT-TÜRKİYE