Skip to content
Research Article Peer ReviewedAt least two reviewers Open Access

Comparison of PID and FLC type controller designed for ohmic heating system

1Atatürk University
✉ Corresponding author: Buket Dinç · buket.dinc@atauni.edu.tr
PDF BibTeX RIS

Abstract

In this study, mathematical modeling of an ohmic heating system has been done, firstly. Then, two different control approaches, PID and fuzzy logic control, have been considered to control of mathematically modeled ohmic heating system. An optimal PID controller has designed based on Ziegler-Nicholas method. In order to make a comparison, a fuzzy logic controller (FLC) has also been designed and obtained results have been compared, finally. Based on the obtained results, FLC has showed more powerful, stable and convenient control action to control of an ohmic heating system. Applying designed FLC, it can be concluded that the ohmic heating system behavior is more stable and has less settling time with no overshoot have been observed.

Keywords

Cite this article

Dinç, B., & Erentürk, K. (2024). Comparison of PID and FLC type controller designed for ohmic heating system. In Proceeding of the Cognitive Models and Artificial Intelligence Conference (pp. 20–24). SET Technology. https://doi.org/10.36287/setsci.17.1.0020

Article History

Published
24 Jun 2024

License

© 2024 SET Technology. This article is distributed under the terms of the CC BY 4.0.

Research Contributions (2019+)Peer reviewed by at least two reviewers
Open AccessCC BY 4.0
Open Discovery Metadata · DOI · OAI-PMH
Global Reachresearchers worldwide